Description
Infant/Child Replacement Electrode Pads Cartridge for the Philips HeartStart HS1 AED. The electrode pads for the Philips HeartStart HS1 model come in a convenient and easy-to-use cartridge format.
The Philips HeartStart HS1 AED Infant/Child Replacement Electrode Pads Cartridge are meant for children eight years or younger, or for those that weigh less than 25kg (55 lbs).
Philips Heartstart HS1 Infant/Child Electrode Pads Cartridge M5072A SMART Pads reduce the defibrillator’s shock energy, so that an infant or child suffering sudden cardiac arrest can be treated successfully. The Heartstart Infant/Child Electrode Pads Cartridge is marked with an indication of the appropriate weight and with a teddy bear icon for ready identification.
Features:
- When the Infant/Child Pads Cartridge is installed in the HS1 AED, the HS1 AED automatically reduces the defibrillation energy to an energy level more appropriate for infants and children.
- With the Infant/Child Pads Cartridge inserted, the HS1 AED automatically reduces the defibrillation energy from the adult dose of 150 joules to 50 Joules and provides optional infant/child CPR Coaching.
- Electrode placement direction illustrates exactly where to place the electrodes on the victim.
The Philips Heartstart HS1 AED Defibrillator uses two self-adhesive defibrillation/monitoring pads to monitor ECG signals and, if necessary, to deliver defibrillation energy to the patient. These pads (also known as electrodes) are provided in a single-use, disposable package.
HeartStart Infant/Child SMART Pads reduce the energy therapy for younger patients under 8 years or weighing less than 25kg (55 lbs), including infants.
All pads are sold with minimum 24months of shelf life upon delivery. Expiration date is noted on pads.
Manufacturers Part Number: M5072A
Additional information
Specifications
HeartStart Infant/Child SMART Pads are appropriate for cardiac arrest victims weighing less than 25kg (55 lbs) or more.
All pads are sold with minimum 24months of shelf life upon delivery. Expiration date is noted on pads.
Suitable only for use with the Philips HeartStart HS1 AED.
Manufacturers Part Number: M5072A
Use with Non-Philips Healthcare Equipment |
|
---|---|
Use with Philips Healthcare Equipment |
|
Single-Patient Use OR Multi-Patient Use |
|
CE Certified |
|
Packaging Unit |
|
Use with Other Supplies |
|
Package Weight |
|
Minimum Shelf Life |
|
Product Category |
|
Sterile OR Non-Sterile |
|
Not manufactured with natural rubber latex |
|
Product Type |
|
Patient Application |
|
---|---|
Recommended Patient Weight |
|
Leadwire Length |
|
Conductor Surface Area |
|
Temperature Range for Storage |
|